CA-PRO Cyanoacrylate Fuming Chamber
Forensic Fingerprint Development

CA-PRO Cyanoacrylate Fuming Chamber

Develop latent prints on non-porous evidence in a fully automated, monitored and documented cycle. The CA-PRO controls humidity, temperature, contact time and purge from a colour touchscreen, and records every run against a case number.

Control
Colour touchscreen, automated
Cycle
One touch, three stages, monitored
Record
USB & SD data logging
Sizes
0.66m / 0.9m / 1.5m / Custom

Latent print development on non-porous evidence. Police forces and fingerprint bureaux, accredited forensic laboratories, evidence recovery units, and forensic teaching and training.

Fingerprint bureaux Forensic labs Evidence units Scenes of crime Training
Why control matters

Cyanoacrylate fuming is only as good as the conditions

Superglue fuming develops latent prints because cyanoacrylate vapour polymerises onto the residue left by a finger. It works, but it is sensitive: get the humidity or the contact time wrong and you get weak, over-developed or inconsistent results on evidence you may only get one chance with.

The CA-PRO takes that guesswork away. Load the evidence on the adjustable hanging rods, place the cyanoacrylate on the hotplate, enter the case details and start the cycle. From there the chamber controls the humidifier, hotplate, circulation fan, door lock and purge automatically, and logs what actually happened.

  • ✓Automated three-stage cycle, run the same way every time
  • ✓Humidity and hotplate temperature held to setpoint and recorded
  • ✓Ductless and recirculating, with a carbon filter and purge cycle
  • ✓Case number and officer ID captured against every run

Standard on every CA-PRO

Every chamber ships with the full control and recording system.

Colour touchscreenHumidity controlHotplate controlDoor lockPurge cycleUSB & SD logging
The cycle

One press, three controlled stages

Start the cycle and the chamber works through humidifying, vapourising and purging on its own, showing you exactly what is running and where it is up to at every moment.

Stage 1

Humidifying

The humidifier and recirculation fan bring the chamber up to the relative humidity setpoint before any fuming begins, so the print residue is properly conditioned. The hotplate stays off until conditions are right.

Stage 2

Vapourising

The hotplate warms the cyanoacrylate and the fan circulates vapour evenly around the evidence. Contact time counts down on screen against the preset, with live humidity and temperature shown throughout.

Stage 3

Purging

The purge fan clears the remaining cyanoacrylate vapour through the carbon filter before the door unlocks, so the operator is not exposed when they open up. The run can then be transferred to USB.

Control system

Everything on one screen, nothing left to guesswork

The colour touchscreen puts the whole process in front of the operator, from selecting a cycle to calibrating the humidity probe. Presets can be adjusted in seconds, and two user-defined cycles sit alongside the standard one.

  • 1 Standard and user-defined cycles Run the fixed standard cycle, or set up and save two of your own with your choice of humidity, temperature, contact, purge and UV times.
  • 2 Adjustable parameters Purge time, RH timeout, contact time, hotplate temperature and UV time are all set from the screen, with defaults you can reload at any point.
  • 3 Live cycle monitoring Current and setpoint humidity, current and set temperature, and both preset and elapsed timers are shown as the cycle runs.
  • 4 Cancel with a record If the prints are clearly developed, the operator can end contact early. The system asks for confirmation and records whether the cycle completed or was ended by the operator.
  • 5 Diagnostics and calibration An on-board diagnostics screen shows every input and output at a glance, and the humidity probe can be calibrated against a certified meter with a stored offset.
EVIDENCE INTEGRITY

A record you can put your name to

Reproducibility and documentation matter as much as the result, particularly for laboratories working to accreditation standards. The CA-PRO is built so that every run can be tied to a case and an operator, and the conditions it ran under can be produced afterwards.

  • ✓ Case number and officer ID entered before the cycle starts
  • ✓ Process data logged and transferred out by USB or SD card
  • ✓ Door locks during the cycle, with a lock alarm if it is disturbed
  • ✓ Humidity probe calibration against a certified meter, with the offset stored
  • ✓ Cancelled cycles recorded as operator-ended, not quietly dropped
Where it's used

Built around the way evidence is actually processed

Cyanoacrylate fuming develops latent prints on non-porous surfaces such as glass, metal and plastics. These are the settings the CA-PRO is built for.

Fingerprint bureaux

Routine, high-volume development of latent prints on recovered non-porous items, with a repeatable cycle that gives comparable results between operators and between shifts.

Accredited laboratories

Where reproducibility and documentation have to be demonstrated, the logged cycle data, case and officer capture and calibration record all support the evidence trail.

Evidence recovery units

Process items from seizure through to examination in one place, with the door locked during the cycle and the vapour purged before anyone opens up.

Larger and awkward items

The taller models take bulkier exhibits on adjustable hanging rods and shelves, so items that will not fit a benchtop chamber can still be fumed properly.

Training & teaching

Forensic science courses and in-force training benefit from a chamber that shows each stage on screen, so trainees can see what the process is actually doing.

Ready where you need it

Ductless and recirculating, so no ducting is required. On its stand with castors the chamber can be repositioned as the lab layout changes.

Configurations

Three sizes, benchtop to floor-standing

Choose the chamber to suit the exhibits you handle and the space you have. Custom builds are available where a specific size or fit-out is needed.

ModelWidthFormatTypical use
CA-PRO-600.66mBenchtopSmaller exhibits, limited bench space
CA-PRO-900.9mBenchtop or on standGeneral casework, the popular size
CA-PRO-1501.5mFloor-standingLarger volumes, bulkier and taller exhibits
CustomBespokeTo suitBuilt to your size and fit-out

All models share the same touchscreen control system, three-stage automated cycle, humidity and hotplate control, door lock, purge cycle and USB data logging. Supplied with humidifier, trays, shelf brackets and bars, prefilter, keys, manual and stylus. Full dimensions and datasheet available on request.

Filtration

Purged through a dedicated carbon filter

Cyanoacrylate vapour is not something to vent into the lab. At the end of every cycle the purge fan draws the chamber air through a carbon filter specified for cyanoacrylate, with a prefilter capturing particulate first, so nothing hazardous is released into the room.

Cyanoacrylate carbon filter Prefilter Automatic purge stage No ducting required
Purge
The door stays locked until the purge stage has cleared the chamber, so the operator is not exposed on opening
Key features

Built for casework, day in and day out

Colour touchscreen control

The full cycle, parameters, diagnostics and calibration are driven from one screen, with on-screen help against each function.

Automated three-stage cycle

Humidifying, vapourising and purging run in sequence without operator intervention, so every case is treated the same way.

Humidity control & calibration

The chamber holds relative humidity to setpoint, and the probe can be calibrated against a certified meter with the offset stored.

Controlled hotplate

Hotplate temperature is held under PID control with an auto-tune routine and a safety cut-out, for consistent vapourising.

Door lock & interlock

The door locks for the duration of the cycle with a lock alarm, and the UV lamps switch off automatically if the door is opened.

UV decontamination

Timed UV lamps decontaminate the clean, dry chamber between cases, helping guard against carry-over between exhibits.

USB & SD data logging

Cycle data is recorded against the case number and transferred out by USB or SD card for the file.

Ductless and mobile

Recirculating design means no ducting to install, and the stand with castors lets the chamber be moved when needed.

Easy to clean interior

A smooth, wipe-down chamber with removable trays, shelves and hanging rods to reposition around the exhibit.

Get a quote

Tell us the size and how you work

Send us the model you need and a little about your casework, and we'll come back with a specification and price, typically within four working hours.

Your requirements

Mounting

Optional accessories

Contact details

Or email us directly at office@fumecare.com